The Differential probe SI-9002 Amt emulator mac download. extends the measurement power of oscilloscopes to power semiconductor circuits. This Differential Probe provides any general oscilloscope with a high voltage differential input.
Sports Instruments Si 90 Wl Manual Youtube
The Differential probe SI-9002 is small and light, so it can be used in a very convenient way; just plug it into the input of, for example, the Handyscope HS5. The wide bandwidth and the high accuracy of this Differential Probe cater for a wide range of applications.
Category:Probes
Page 1 C O N T A C T I N G S P O R T S I N S T R U M E N T S S I 9 0 H R O W N E R ’ S M A N U A L SPORTS INSTRUMENTS USA 2064 PROSPECTOR AVE.; Page 2 The SI 90HR is the worlds first Bicycle riding is an inherently dangerous activity.; Page 3 H O W A H E A R T R A T E M O N I T O R W O R K S ALWAYS: Rinse your Sports Instruments heart rate transmitter Your new Sports Instruments Heart. Leading international supplier of automotive electronics & mechatronics. A cookie is a small data file that is stored on your terminal device. Cookies are used to analyze user interest in our websites and help make them more user-friendly. Note: By using our website you agree to our use of cookies. Cookies help us to provide our services. – More information I agree. Aug 05, 2008 Sports Instruments (SI) was a Utah based company with 3-4 employees that was sold to Bell Sports in 2004 (and Bell Sports was later sold to Easton Sports in 2006). SI's activities had slowed, and it is reasonable to believe that SI Pro, Fit and ECG Heart Rate. If by 'open' you mean run - then certainly yes.Quoting the manual: You invoke the resulting P-code file in the same way you invoke the MATLAB.m source file from which it was derived. Decrypt P File Matlab Help - mnogosoftagolden4t2. DES crypt and decrypt a text file by MATLAB. This feature is not available right now. Please try again later.
Using a built-in differential amplifier, the Differential probe SI-9002 scales and converts the high voltage differential input to a low voltage single ended BNC output. The differential input is useful in measurements of power semiconductor circuits, as no reference to ground is required. Both the positive and negative sides of the balanced input possess high voltage differential input up to 700 V, and its sensitivity can extend down to 100 mV. With high bandwidth and high response speed, the Differential probe SI-9002 is adequate for accurate dV/dt measurement in the fastest switching circuits of thyristors, bipolar transistors, or power MOSFETS.
![Instruments Instruments](https://images-na.ssl-images-amazon.com/images/I/61macu9DWYL._SL1500_.jpg)
The table below shows detailed specifications of the Differential probe SI-9002.
Differential probe SI-9002 - Specification | |
---|---|
Bandwidth | DC to 25MHz (-3dB) |
Attenuation Ratio | 1/20 or 1/200 |
Accuracy | ±2% |
Rise Time | 14 ns |
Input Impedance | 4 MOhm 5.5 pF each side ground |
Input Voltage | |
Differential Range 1 | |
1/20 | ±140 V (DC+Peak AC) or 140 Vrms |
1/200 | ±1400 V (DC+Peak AC) or 1000 Vrms |
Common Mode Range | ±1400 V (DC+Peak AC) or 1000 Vrms |
Absolute Max. Voltage 1 | ±1400 V (DC+Peak AC) or 1000 Vrms CAT III |
Output | |
Swing (into 2k ohm load) | +/-7 V |
Offset (typical) | <+/-5 mV |
Noise (typical) | 0.7 mVrms |
Impedance (typical) | 50 Ohm (for using 1 MOhm input system oscilloscope) |
CMRR (typical) | -80 dB @ 50 Hz, -60 dB @ 20 kHz |
Ambient | |
Operating Temperature | -10 to 40 °C (14 to 104 F) |
Storage Temperature | -30 to 70 °C (-22 to 158 F) |
Operating Humidity | 25 to 85% RH |
Storage Humidity | 25 to 85% RH |
Power Requirements | Standard 4 x AA cells or regulated 9 VDC / 40mA mains adapter 2 |
Length of BNC Cable | 95 cm (37.4 inch) |
Length of Input Leads | 45 cm (17.7 inch) |
Weight (differential probe and PVC jacket) | 400 g (14.1 ounce) |
Dimensions | |
Height | 21 mm (0.8 inch) |
Length | 170 mm (6.7 inch) |
Width | 63 mm (2.5 inch) |
|
When using the Differential probe SI-9002 in combination with:
- Handyscope HS6 DIFFwithout option SafeGround
- WiFiScope WS6 DIFFwithout option SafeGround
an extra grounding connection between the instrument and the Differential probe SI-9002 is required. When ordering a Differential probe SI-9002 to be used with one of these instruments, please mention that you also want the extra ground lead for the Differential probe SI-9002 and specify for which instrument.
Information: When using the Differential probe SI-9002 in combination with
- Handyscope HS6 DIFFwith option SafeGround
- WiFiScope WS6 DIFFwith option SafeGround
the used input channel of the scope must be set to single ended. Windows 10 desktop.ini [viewstate].
The Differential probe SI-9002 is delivered with:
Amount | Item |
---|---|
1 | Differential probe SI-9002 |
1 | Protective rubber shell |
1 | Manual |
Sports Instruments Si 90 Wl Manual Free
Description | Version | Remarks | Size | |
---|---|---|---|---|
Differential probe SI-9002 user manual | 1.1 | English | 101.69 kB | download |
Measuring a power outlet
What is involved in measuring a mains power outletRead whole article.
Sports Instruments Si 90 Wl Manual 2017
Differential measurements
Information about doing differential measurementsRead whole article.